Description |
SIMpull THHN THWN, 600 Volts. Copper Conductor, Thermoplastic Insulation/SIM Nylon Sheath, Heat, Moisture, Gasolin, and Oil Resistant II, also rated MTW and THWN-2, SIM Technology for Easier Pulling |
|
Specifications |
Conductor Size | 10 AWG |
No. of Strands | 1 |
Nominal Outside Diameter | 150mils |
Allowable Ampacity 60°C | 30A |
Allowable Ampacity 75°C | 30A |
Allowable Ampacity 90°C | 30A |
approx. Weight | 36lbs/1000ft (16.34kg/304m) |
|
General Features |
SIMpull THHN or THWN-2 or MTW (also AWM) comply with: |
ASTM | All applicable standards |
UL | Standard 83, 1581 and 1063 (MTW) |
T90 | Nylon/TWN75 Sizes through 1000 kcmil CSA C22.2 No. 75 |
NOM-ANCE | 90°C |
Federal Specification | A-A-59544 |
National Electrical Code | NFPA 70 |
VW-1 | Sizes 14 through 1 AWG |
CT | rated in sizes 1/0 AWG and larger |
FT1 | yes |
AWM | Sizes 14 through 6 AWG. MTW available in stranded only |
NEMA | WC-70 Construction Requirements |
RoHS/REACH Compliant | yes |
|
Construction |
• | SIMpull THHN or THWN-2 or MTW copper conductors are soft annealed copper. #14 - 4/0 AWG uses a combination unilay strand and 250 kcmil and larger uses a compressed copper strand. |
|
• | The wire is insulated with a tough heat and moisture resistant poly vinyl chloride (PVC), over which a SIM (SLIKQWIK Infused Membrane) nylon (polyamide) or UL Recognized equal jacket is applied. |
|
• | Available in black, white, red, blue, purple, green, yellow, orange, brown and gray. Some colors are subject to economic order quantity. |
|
• | Marked sunlight resistant in sizes 2 AWG and larger. |
|
• | THWN-2 available in sizes 8 AWG and larger . |
|
• | Sizes 14 to 10 AWG are available with SIMpull Technology only in SIMpull Barrel configurations. |
|
|
Applications |
SIMpull THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code. |
Voltage for all applications is 600 volts. |
SIMpull THHN conductors are designed to be used without application of pulling lubricant. |
Allowable temperatures are as follows: |
• | THHN or T90 Nylon: Dry locations not to exceed 90°C |
|
• | THWN-2: Wet or dry locations not to exceed 90°C or locations not to exceed 75°C when exposed to oil |
|
• | TWN75: Wet locations not to exceed 75°C |
|
• | MTW: Wet locations or when exposed to oil at temperatures not to exceed 60°C or dry locations not to exceed 90°C (with ampacity limited to that for 75°C conductor temperature per NFPA 79) |
|
– AWM: Dry locations not to exceed 105°C when rated and used as appliance wiring material |
|
Standard Packing/Put-Ups |
|
|
|
Notes |
• | * Sizes 14 to 10 AWG available with patented Sim Technology No Lube jacket only in SIMpull Wire Barrel configurations. |
|
Specifications and information are nominal and are subject to change without notice.