United Kingdom |
|
|
RCD Protected Switchsocket Outlets |
|
FEATURES |
|
|
|
• Suitable for most residential, commercial and light industrial applications • Active and passive control circuit applications • Flexible and versatile in use • Single Sockets have double pole • switching, double sockets are single pole switching • Masterseal Plus products are ideal or use with equipment subject to wet weather or high humidity • Part of a complete range of circuit protection devices • They are a.c. and pulsating d.c. sensitive for residual current • Double Socket products have an enhanced RF Immunity performance |
|
|
|
|
|
|
Catalog Number |
Description |
Stock |
LOGIC PLUS FLUSH, Dimensions (86 x 146)mm, Fixing Centres 120.6mm |
|
1 Gang DP, 30mA Rated, Tripping Current, Active Control Circuit, White |
|
K6303WHI |
1 Gang DP, 30mA Rated, Tripping Current, Passive Control Circuit, White |
|
K6231WHI |
2 Gang SP, 30mA Rated, Tripping Current, Active Control Circuit, White |
|
K6233WHI |
2 Gang SP, 30mA Rated, Tripping Current, Passive Control Circuit, White |
|
|
|
|
|
|
|
Catalog Number |
Description |
Stock |
ALBANY PLUS FLUSH, Dimensions (86 x 146)mm, Fixing Centres 120.6mm |
K6301BRC |
1 Gang DP, 30mA Rated Tripping Current, Active, Brushed Chrome Finish |
|
|
1 Gang DP, 30mA Rated Tripping Current, Active, Brushed Stainless Steel |
|
K6301PCR |
1 Gang DP, 30mA Rated Tripping Current, Active, Polished Chrome Finish |
|
K6301SAG |
1 Gang DP, 30mA Rated Tripping Current, Active, Satin Gold Finish |
|
K6304BRC |
1 Gang DP, 30mA Rated Tripping Current, Passive, Brushed Chrome Finish |
|
K6304BSS |
1 Gang DP, 30mA Rated Tripping Current, Passive, Brushed Stainless Steel |
|
|
|
|
|
|
|
Catalog Number |
Description |
Stock |
METALCLAD PLUS SURFACE, Dimensions (86 x 147 x 54)mm, Knockouts 8x 20mm |
K6102ALM |
1 Gang DP, 10mA Rated Tripping Current, Active Control Circuit |
|
K6302ALM |
1 Gang DP, 30mA Rated Tripping Current, Active Control Circuit |
|
|
1 Gang DP, 30mA Rated Tripping Current, Passive Control Circuit |
|
K6231ALM |
2 Gang SP, 30mA Rated Tripping Current, Active Control Circuit |
|
K6233ALM |
2 Gang SP, 30mA Rated Tripping Current, Passive Control Circuit |
|
|
|
|
|
|
|
Catalog Number |
Description |
Stock |
MASTERSEAL PLUS IP66 SURFACE, Dimensions (157 x 175 x 89)mm |
|
1 Gang DP, 30mA Rated Tripping Current, Active Control Circuit, Gray |
|
|
1 Gang DP, 30mA Rated Tripping Current, Active Control Circuit, White |
|
|
1 Gang DP, 30mA Rated Tripping Current, Active Control Circuit, Black |
|
|
2 Gang SP, 30mA Rated Tripping Current, Active Control Circuit, Gray |
|
|
2 Gang SP, 30mA Rated Tripping Current, Active Control Circuit, White |
|
|
2 Gang SP, 30mA Rated Tripping Current, Active Control Circuit, Black |
|
K56233GRY |
2 Gang SP, 30mA Rated Tripping Current, Passive Control Circuit, Gray |
|
K56233WHI |
2 Gang SP, 30mA Rated Tripping Current, Passive Control Circuit, White |
|
K56233BLK |
2 Gang SP, 30mA Rated Tripping Current, Passive Control Circuit, Black |
|
|
|
|
|
|
|
Please contact our sales office for further information and availability. Non stock products have a minimum order quantity. |
|
|
|
|
|
Sentrysocket |
|
Compliance with EC Directives, Standards and approvals |
|
All Sentrysockets comply with the following EC Directives and are CE marked: |
|
Low Voltage Directive Electromagnetic Compatibility Directive (89/336/EEC) |
|
Sentrysocket RCD DP Single Sockets comply with the requirements of the following standards: |
|
BS 7288:1990 BS EN 50082-1:1998 |
|
Sentrysocket RCD SP Double Sockets also comply with the requirements of BS EN 61543:1996. |
|
|
Description |
Sentrysocket provides a high level of protection against electrocution and gives further protection when used with appliances vulnerable to insulation damage, particularly when they are in damp environments or outdoors. The Sentrysocket units are not suitable for mounting in damp environments or outdoors. Sentrysocket, incorporating an RCD, is part of a complete range of fixed and portable wiring devices and circuit protection devices suitable for use in domestic, commercial and light industrial applications. |
|
Active Control Circuit |
This version of Sentrysocket incorporates a ′RE-SET′ mechanism and is mains failure sensitive ie. it will function under all normal conditions expected of an RCD but it will also trip in the event of a power cut or a dramatic reduction in mains voltage. This makes it ideal for use where hazardous situations could occur due to equipment such as rotating machinery and heat developing apparatus becoming suddenly energised after a power cut. |
|
Passive Control Circuit |
This version of Sentrysocket incorporates a ′STAY-SET′ mechanism and is mains failure proof ie. it will function under all normal conditions expected of an RCD but will not trip in the event of a power cut. This makes it suitable for freezers or use in inaccessible or unmanned locations. |
|
|
|
TECHNICAL SPECIFICATION |
|
ELECTRICAL |
| |
RATED VOLTAGE | 240V a.c. |
CURRENT RATING | 13A resistive, Rated tripping current 10mA/30mA |
TERMINAL CAPACITY | 3 x 4mm² for 1 gang 2 x 4mm² for 2 gang |
PHYSICAL |
| |
AMBIENT OPERATING TEMPERATURE | –5°C to +40°C |
IP RATING | IP2XD IP66 (K56301/K56231/K56233) |
MAX. INSTALLATION ALTITUDE | 2000 metres |
|
Sentrysockets are not suitable for connection across two lines of a 127V line to Neutral Voltage System |
|
|
Please contact our sales office for technical information not listed here. |
|
Specifications and information are nominal and are subject to change without notice.