Low Bay Industrial Lighting with internal Reflector |
|
|
|
|
Intended Use |
• | For areas that require optimum vertical illumination with glare control at low mounting heights. Ideal for parking garages, greenhouses, garden centers and low-profile industrial aisles. |
|
• | Certain airborne contaminants can diminish integrity of acrylic. |
|
|
Construction |
• | Housing: Rugged, heavy-duty, die-cast aluminum housing. |
|
• | Standard finish is natural aluminum polyester powder finish. |
|
|
Optics |
• | Internal reflector is finished in a high reflectance white polyester powder finish. |
|
• | Precision injection-molded, virgin acrylic closed-bottom refractor. |
|
• | The assembly closes by way of (2) screws, which can be changed to tamperproof screws that are supplied. |
|
|
Electrical |
• | Ballast: All ballasts are 100% factory tested. HPS: Constant wattage autotransformer; MH: Super CWA Pulse Start ballasts, 88% efficient and EISA legislation compliant, are required for 250-450W (must order SCWA option) for US shipments only. CSA, NOM or INTL required for probe start shipments outside the US. |
|
• | Socket: Vertically oriented mogul base PROTECTED EXCLUSIONARY base "PINK" socket with copper alloy nickel plated screw shell and center contact. For use with "O" rated protected metal halide lamps only. |
|
|
|
Installation |
• | Quick-Mount® attachment plate mounts to 4" square or octagonal J-box, which may be surface or recessed mounted. |
|
• | Fixture is hinged to Quick-Mount plate for easy installation. |
|
• | Once wiring connections are made, fixture is twist-locked into place and secured in a tamper-proof installation. |
|
• | Internal trigger mechanism releases fixture from J-box. |
|
• | The Quick-Mount attachment must be installed to rigid mounted J-box. |
|
• | Factory installed pendant mount option (PM) available. |
|
|
Compliances |
• | UL listed for damp locations. -30°C to 40°C ambient operation. |
|
• | UL wet location available (see Options). |
|
• | 150MP standard with WL option. |
|
• | UL Listed to U.S. and Canadian safety standards (see Options). |
|
• | NOM Certified (see Options). |
|
|
Note: Specifications subject to change without notice. |
|
|
|
|
|
|
|
|
|
|
|
|
Products |
Catalog No. |
Configuration |
Description |
|
|
TGR 100S A125 120 LPI |
Low Bay Industrial Lighting, 100W High Pressure Sodium (Lamp included), 120V, rugged, heavy-duty, die-cast Aluminum Housing, Reflector A125, damp locations,-30°C to 40°C ambient operation, UL |
|
TGR100SA125120LL |
TGR 100S A125 120 L/LP |
Low Bay Industrial Lighting, 100W High Pressure Sodium (less Lamp), 120V, rugged, heavy-duty, die-cast Aluminum Housing, Reflector A125, damp locations,-30°C to 40°C ambient operation, UL |
|
TGR100SA125208LL |
TGR 100S A125 208 L/LP |
Low Bay Industrial Lighting, 100W High Pressure Sodium (less Lamp), 208V, rugged, heavy-duty, die-cast Aluminum Housing, Reflector A125, damp locations,-30°C to 40°C ambient operation, UL |
|
TGR100SA125277LP |
TGR 100S A125 277 LPI |
Low Bay Industrial Lighting, 100W High Pressure Sodium (Lamp included), 277V, rugged, heavy-duty, die-cast Aluminum Housing, Reflector A125, damp locations,-30°C to 40°C ambient operation, UL |
|
|
|
|
|
|
|
|
|
Catalog No. |
Description |
Note(s) |
HKF |
Fixture hook female |
11,12 |
HKM |
Fixture hook male |
11,12 |
HKMG |
Grommeted fixture hook male |
11,12 |
LPF |
Fixture loop female |
11,12 |
LPM |
Fixture loop male |
11,12 |
LPMG |
Grommeted fixture loop male |
11,12 |
TPH |
Through-wire power hook |
10 |
PPH |
Pendant power hook |
10 |
SCK |
60" Safety chain kit |
|
|
|
|
|
|
|
|
|
|
|
Note |
Description |
|
1 |
Medium base only. |
|
2 |
Must be ordered with WL option to comply with EISA regulations. |
|
3 |
These wattages comply with California Title 20. |
|
4 |
Not available in Canada. |
|
5 |
Optional multi-tap ballast (120, 208, 240, 277V; 120, 277,347V for Canada.) |
|
6 |
Must specify voltage/tap position. Not available in 150 watt metal halid |
|
7 |
Option is not field installable, must be factory installed. |
|
8 |
Lamp not included. |
|
9 |
Quartz lamp wattage not to exceed 100W. |
|
10 |
Must use PM option. |
|
11 |
Not suitable for wet locations. |
|
12 |
20A standard 480V. |
|
13 |
Available for shipment outside of U.S. only. |
|
14 |
May be ordered with 10′, 15′, 20′ cords. |
|
15 |
Specify circuit/tap position. |
|
16 |
When using Reloc with Kilowatch, the LOCU or HOCU option must be used with E or F conductors. Consult factory for 208, 240, 480V. |
|
17 |
For specific ordering information, refer to the current Lithonia Product Selection Guide. |
|
18 |
Consult factory for availability in Canada. |
|
|
|
|
|
|
|
|
|
|
|
|
| Further Products |
Product image |
Product group and Description |
|
|
Explosion-Proof High Pressure Sodium Luminaires, Series LMV, 35W to 150W, Stanchion Mount, Cl. I, Div 2, Groups A, B, C, D, NEMA 3, 3R, 4, 4X, IP66 |
|
|
Explosion Proof High Pressure Sodium Luminaires, VMV High Wattage Series, 200W to 400W, Cl. I, Div. 2, Groups A, B, C, D, NEMA 3, 3R, 4, 4X, IP56 to IP66 |
|
|
Explosion-Proof High Pressure Sodium Luminaires, Series LMV, 35W to 150W, Ceiling Mount, Cl. I, Div 2, Groups A, B, C, D, NEMA 3, 3R, 4, 4X, IP66 |
|
|
Incandescent Non-Metallic Corrosion Resistant Hazardous Fixtures, NV2 Series |
|
|
Explosion-Proof Emergency Compact Fluorescent Luminaires, Series DMVFB, continous Operation, Cl. I, Div. 2, Groups A, B, C, D, NEMA 3, 3R, 4, 4X, IP66 |
|
|
Select desired product group above to get further informations. |
|
|
|
|
|
|
|
|
Specifications and information are nominal and are subject to change without notice.