USA, Canada, International |
Rev 27.April.2018 |
|
2 pole version illustrated |
IEC/EN 61008-1 • UL 1053 |
|
UL 1053 residual current circuit breakers already protected upstream by a shortcircuit and overload protection device are used for: |
|
• | control and disconnection of electric circuits |
|
• | protection of people against electric shock by direct and indirect contacts |
|
• | protection of installations against insulation faults |
|
• | enhanced continuity of supply, during a series of close lightning strokes, IT earthing system, equipment including interference suppression filters, variable speed controllers, frequency converters, electronic ballasts for lighting |
|
• | enhanced earth leakage protection: in presence of harmonics or high frequency rejections. |
|
|
They comply with RCD standards UL 1053 and IEC/EN 61008. |
|
A-SI type GFPs are ideal for operation in environments with a humid atmosphere and/or polluted by aggressive agents: swimming pools, marinas, agri-food industries, water treatment stations, industrial sites, etc. |
|
|
|
|
|
Product data sheet |
Characteristics |
|
M9R81225 |
Multi 9 - GFP - RCCB - 2P - 25A - class A SI - 240 V - 26 mA instantaneous |
|
|
Main |
| |
Range | Multi 9 |
Product name | Multi 9 GFP |
Product or component type | Residual current circuit breaker (RCCB) |
Device short name | GFP |
Device application | Distribution |
Poles description | 2P |
Neutral position | Left |
[In] rated current | 25A at 40°C conforming to EN/IEC 61008-1 |
Network type | AC |
Earth-leakage sensitivity | 26mA conforming to UL 1053, 30mA conforming to EN/IEC 61008-1 |
Earth-leakage protection time delay | Instantaneous |
Earth-leakage protection class | Type A-SI |
Utilisation category | AC-23A conforming to EN/IEC 61008-1 |
|
|
Complementary |
| |
Network frequency | 50/60 Hz |
[Ue] rated operational voltage | 240V AC 50Hz, 120V AC 60Hz, 230V AC 50Hz, 240V AC 60Hz |
Residual current tripping technology | Voltage independent |
Rated breaking and making capacity | Idm 1500A conforming to EN/IEC 61008-1 |
Rated conditional short-circuit current | Inc 10kA 100A gG |
[Ui] rated insulation voltage | 440V AC 50/60Hz |
[Uimp] rated impulse withstand voltage | 6kV conforming to EN/IEC 61008-1 |
Contact position indicator | Yes |
Control type | Toggle |
Local signalling | ON, OFF, fault trip |
Mounting mode | Clip-on |
Mounting support | DIN rail |
9 mm pitches | 4 |
Height | 81mm |
Width | 36mm |
Depth | 60mm |
Product weight | 0.22kg |
Color | Grey |
Mechanical durability | 20000 cycles |
Locking options description | Padlocking in OFF position |
Connections - terminals | Tunnel type terminals, top or bottom flexible wire(s) 1...25mm² max (AWG 18...AWG 3) Tunnel type terminals, top or bottom rigid wire(s) 1...35mm² max (AWG 18...AWG 2) Tunnel type terminals, top or bottom flexible with ferrule wire(s) 1...25mm² max (AWG 18...AWG 3) |
Wire stripping length | 14mm (top or bottom) |
Tightening torque | 3.5 N.m (top or bottom) |
|
|
Environment |
| |
Standards | EN/IEC 61008-1, UL 1053 |
Product certifications | UL, CSA, CCC, IEC |
IP degree of protection | IP40 for modular enclosure conforming to IEC 60529 IP20 conforming to IEC 60529 |
Pollution degree | 3 |
Electromagnetic compatibility | 8/20 µs impulse withstand, 3000A conforming to EN/IEC 61008-1 |
Tropicalisation | 2 conforming to IEC 60068-1 |
Relative humidity | 95% (55°C) |
Ambient air temperature for operation | -25...60°C |
Ambient air temperature for storage | -40...70°C |
|
|
|
Please contact our sales office for additional information not listed here. |
|
|
|
Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. |
|
Specifications and information are nominal and are subject to change without notice.