Catalog No. : 5279-CWP
EDP Number : 115072
Target Countries : USA, Canada, Mexico
Description :
Power Outlet Receptacle, 15 Amp, 125 Volt, NEMA 5-15R, 2-Pole 3-Wire Grounding (2P+E), Straight Blade, Industrial Grade, Standard Wire Wells Wired, Nylon Strap, Gray
Country of origin : US – UNITED STATES
Taric Number : 85366990
Subject to change
Brandname : Leviton
TECHNICAL INFORMATION
Logistic Informations
Standard qty. : 900 Each
Carton quantity (VPE) : 10 Each
Shipping weight : 0.220 kg / Each
Gross volume : 1.095 m³ / 1000
Net weight : 0.153 kg / Each
Product Features
Device Type : Flanged Outlet
Configuration : NEMA 5-15R
Plug Style : IEC Type B
Contact Style : Straight Blade
Termination : Standard Wire Wells
AC Horsepower Ratings
At Rated Voltage : 1/2 HP
Electrical Specifications
Rated Current : 15 Amp
Rated Voltage : 125 Volt AC
Poles and Wires : 2P 3W Grounding (L+N+PE)
Current Limiting : Full Rated Current
Dielectric Voltage : Withstands 1500V per UL498
Temperature Rise : Max 30°C after 250 cycles OL at 200 percent rated current
Mechanical Specifications
Product ID : Ratings and NEMA I.D. permanently marked on device
Screw Terminal Torque : 10-14 in-lbs
Terminal Accom. : 18-10 AWG
Terminal ID : Brass-Hot, Green-Ground, Silver-Neutral
Material Specifications
Body Material : Thermoplastic Nylon
Device Color : Gray
Cover and Plate Material : Glass-Filled Thermoplastic
Face Material : Thermoplastic Nylon
Grounding Screw : Brass 8-32
Line Contacts : Brass
Strap Material : Thermoplastic Nylon
Terminal Screws : Brass 10-32
Environmental Specifications
Flammability : Rated V-2 per UL 94
Operating Temperature : -40°C to +60°C
IP 64 : Suitability Rating
(protected against dust and splashing water)
NEMA Type 3R : Enclosure Rating when properly installed (protected against rain, sleet and damage from external ice formation)
Standards and Certifications
USA : UL498 Listed (File E13397)
Mexico : NOM Certified (057)
Canada : CSA C22.2 No. 42 (File 016347_0_000 Class 4413-02) Non-metallic weatherproof coverplates Cat Nos 5278, 5279, Type 3R, (Code IP64)
ANSI : C-73
NEMA : WD-6
RoHS Status : Compliant
Safety Notes
- Installation may only be carried by people (qualified electricians) with relevant electrical engineering knowledge and experiences!
Disposal Information
- Must not be disposed with household waste!
Features and Benefits
- Glass-filled thermoplastic cover and plate provide outstanding impact resistance and durability
- IP Suitability rating of 64 ensures protection against dust particles and splashing water
- NEMA Type 3R enclosure rating ensures protection against rain, sleet and damage from external ice formation
- Dual gaskets, one underneath plate and one under lid to ensure weather-resistant fit
- Polyethylene foam gasket material resists corrosives, petrochemicals and salt found in harsh environments
- Choice of straight-blade or locking configurations
- Stainless steel external hardware resists corrosive effects of moisture
- Rugged mounting plate assures smooth, flush fit on equipment mount panels and resists cracking and breaking
Versatile design offers standard wire wells or slots which accept fork terminals and withstand vibrationEasy-to-reach mounting screw openings are accessible without lifting coverLarge thumb tab makes it easy to open cover with gloved hands in sub-zero temperaturesSmooth surface allows users to place identification label on coverMounts to FS/FD boxes or panels suitable for industrial indoor and outdoor useUL 94V-0 Flammability Rating and UV resistance for outdoor applicationsUL Listed and CSA Certified for Wet Locations when cover is closed Related Products in this Group
5278-CWP
NEMA 5-15P
15A 125VAC
Flanged Inlet
Standard
Terminals
5278-FWP
NEMA 5-15P
15A 125VAC
Flanged Inlet
Slots for
Fork Terminals
5279-CWP
NEMA 5-15R
15A 125VAC
Flanged Outlet
Standard
Terminals
15378-CWP
NEMA 5-20P
20A 125VAC
Flanged Inlet
Standard
Terminals
4715-CWP
NEMA L5-15R
15A 125VAC
Flanged Outlet
Standard
Terminals
Please contact our sales office for additional product information.Sicherheitshinweise
Nur national gültig in Deutschland /
Safety notes only valid in GermanyInstallation nur durch Personen mit einschlägigen elektrotechnischen Kenntnissen und Erfahrungen!*- Durch eine unsachgemäße Installation gefährden Sie:
- Ihr eingenes Leben und das Leben der Nutzer der elektrischen Anlage!
- Mit einer unsachgemäßen Installation riskieren Sie schwere Sachschäden, z.B. durch Brand.
- Es droht für Sie die persönliche Haftung bei Personen- und Sachschäden.
Wenden Sie sich an einen Elektroinstallateur!
* Erforderliche Fachkenntnisse für die Installation
Für die Installation sind insbesondere folgende Fachkenntnisse erforderlich:- Die anzuwendenden "5 Sicherheitsregeln": Freischalten, gegen Wiedereinschalten sichern, Spannungsfreiheit feststellen, Erden und Kurzschließen, benachbarte unter Spannung stehende Teile abdecken oder abschranken
- Auswahl des geeigneten Werkzeuges, der Messgeräte und ggf. der persönlichen Schutzausrüstung
- Auswertung der Messergebnisse
- Auswahl des Elektro-Installationsmaterials zur Sicherstellung der Abschaltbedingungen
- IP-Schutzarten
- Einbau des Elektroinstallationsmaterials
- Art des Versorgungsnetzes (TN-System, IT-System, TT-System) und die daraus folgenden Anschlussbedingungen (klassische Nullung, Schutzerdung, erforderliche Zusatzmaßnahmen etc.).
In der Endanwendung sind folgende Anforderungen der Norm zu prüfen bzw. sicherzustellen
The following requirements of the standard must be checked and respectively ensured at final application:- Schutz gegen elektrischen Schlag / Protection against electric shock
- Aufbau ortsfester Steckdosen und Einbausteckdosen / Construction of fixed socket-outlets
- Temperaturerhöhung / Temperature rise
- Kriechstrecken, Luftstrecken und Abstände durch Vergussmasse und Isolierung / Creepage distances, clearances and distances through sealing compound
GENERAL NOTES
Non stock products are procurement goods, can only be ordered in standard packaging quantities and have a minimum order value. The actual product may differ from the illustration shown. The information provided here is subject to change without notice. The product availability is continuously updated every 15 minutes on working days. The product shown is for the use in the specified country. If no CE reference is included in the product description, the use of this product within the European Union or the CE marking itself is not permitted. The use of non-compliant equipment within the European Union is prohibited by law.
SAFETY NOTES Installation may only be carried by people (qualified electricians) with relevant electrical engineering knowledge and experiences!
DISPOSAL INFORMATION Must not be disposed with household waste!
WEEE No.: DE 54087582 — Information provided in compliance with §18 paragraph 4 sentence 3 WEEE Directive available at
www.bmuv.de