Product availability
Contact our sales office to get additional information
Catalog No. : S42
EDP Number : 123071
Target Countries : USA, Canada, Mexico
Description :
Universal Power Angle Plug, 30 Amps or 50 Amps, 250 Volts AC, NEMA 6-30P or NEMA 6-50P, 2-Pole 3-Wire Grounding (2P+E), Accepts #10 - #6 AWG wire, Cord Diameter 1.10" (27.9 mm) max, UL, CSA, NOM, Thermoplastic, Color: black
Country of origin : MX – MEXICO
Taric Number : 85369010
Subject to change
Brandname : Cooper Wiring
TECHNICAL INFORMATION
Logistic Informations
Standard qty. : 1260 Each
Carton quantity (VPE) : 90 Each
Shipping weight : 0.230 kg / Each
Gross volume : 0.750 m³ / 1000
Net weight : 0.183 kg / Each
General Information
Product Name : Heavy-Duty Universal Angled Power Plug
Description : Heavy duty design and construction make power devices ideal for any high amperage industrial or commercial power connectivity application.
Application : Commercial, Range and Dryer
Mechanical Specifications
Design Type : Straight Blade
Device Grade : Heavy-Duty Industrial Specification Grade
Wiring Method : Back wire
Configuration : NEMA 6-30P, NEMA 6-50P
Connection Type : Screw Terminals
Terminal Accommodation : #10 AWG to #6 AWG
Cord range : 1.10" (27.9mm) max
Features : Non-Grounding Pressure Plates to Protect Wires
Torque Rating : 20 lbf-inch
Voltage Ratings : Permanently marked on device
Environmental Specifications
Flammability : Meets UL94 requirements, V0 rated
Temperature rating : -20°C to +60°C (-4°F to +140°F)
Material Specifications
Material : Vinyl
Plug Outer Shell : PVC
Housing Color : Black
Contact Material : Brass
Blades : 0.096" thick (2.4mm) Brass
Terminal Clamps : Zinc Plated Steel
Terminal Screws : 1/4-28 Set Screw, Zinc Plated Steel
Ground Screw : 1/4-28 Set Screw, Zinc Plated Steel
Assembly/Mounting Screws : #8-32 Zinc Plated Steel
Cord Clamp Screws : #8-32 Zinc Plated Steel
Cord Clamp : Zinc Plated Steel
Electrical Specifications
Rated Current : 30 Amp or 50 Amp
Rated Voltage : 250 Volt AC
Poles and Wires : 2P 3W Grounding (L+N+PE)
Dielectric Voltage : Twice the device rating + 1000V per UL498
Current interrupting : Yes, at fullrated current
Temperature rise : Max. 30°C (86°F) after 50 cycles of overload @ 150% of rated current (DC)
Testing and Code Compliance
U.S.A. : Listed to UL498 (E15012), c(UL)us 351B
Mexico : NOM Certified (426)
Canada : CSA certified to C22.2, no. 42-99 (File 2081 Class 6221-02)
Please contact our sales office for additional product information.Universal Power Plugs
Model S41 : 30 Amp 125 Volt AC (NEMA 5-30P) or 50 Amp 125 Volt AC (NEMA 5-50P)
Model S42 : 30 Amp 250 Volt AC (NEMA 6-30P) or 50 Amp 250 Volt AC (NEMA 6-50P)
Target Countries : North America
Features
- Ideal for any high amperage industrial or commercial power connectivity application.
- Universal plugs include blades for both 30A and 50A configurations of the same voltage.
- Versions with 125 Volt AC and 250 Volt AC.
- 2-Pole 3-Wire Grounding (2P+E)
- Terminals have pressure plates to protect wires.
- Rugged high-strength construction.
- Bodies made of abuse-resistant thermoplastic.
- Unique internal clamp design secures cord during assembly, reducing installation time.
- Accepts #10 - #6 AWG wire.
- Cord Diameter 1.10" (27.9 mm) max
- Neoprene gasket seals around cord for added terminal protection from external elements.
- Listed to UL498 (E15012), Listed c(UL)us 351B
- CSA certified to C22.2, no. 42 (002081_0_000 Class 6221-02)
- Mexico NOM Certified (426)
Wiring Instructions
Sicherheitshinweise
Nur national gültig in Deutschland /
Safety notes only valid in GermanyInstallation nur durch Personen mit einschlägigen elektrotechnischen Kenntnissen und Erfahrungen!*- Durch eine unsachgemäße Installation gefährden Sie:
- Ihr eingenes Leben und das Leben der Nutzer der elektrischen Anlage!
- Mit einer unsachgemäßen Installation riskieren Sie schwere Sachschäden, z.B. durch Brand.
- Es droht für Sie die persönliche Haftung bei Personen- und Sachschäden.
Wenden Sie sich an einen Elektroinstallateur!
* Erforderliche Fachkenntnisse für die Installation
Für die Installation sind insbesondere folgende Fachkenntnisse erforderlich:- Die anzuwendenden "5 Sicherheitsregeln": Freischalten, gegen Wiedereinschalten sichern, Spannungsfreiheit feststellen, Erden und Kurzschließen, benachbarte unter Spannung stehende Teile abdecken oder abschranken
- Auswahl des geeigneten Werkzeuges, der Messgeräte und ggf. der persönlichen Schutzausrüstung
- Auswertung der Messergebnisse
- Auswahl des Elektro-Installationsmaterials zur Sicherstellung der Abschaltbedingungen
- IP-Schutzarten
- Einbau des Elektroinstallationsmaterials
- Art des Versorgungsnetzes (TN-System, IT-System, TT-System) und die daraus folgenden Anschlussbedingungen (klassische Nullung, Schutzerdung, erforderliche Zusatzmaßnahmen etc.).
In der Endanwendung sind folgende Anforderungen der Norm zu prüfen bzw. sicherzustellen
The following requirements of the standard must be checked and respectively ensured at final application:- Schutz gegen elektrischen Schlag / Protection against electric shock
- Aufbau ortsfester Steckdosen und Einbausteckdosen / Construction of fixed socket-outlets
- Temperaturerhöhung / Temperature rise
- Kriechstrecken, Luftstrecken und Abstände durch Vergussmasse und Isolierung / Creepage distances, clearances and distances through sealing compound